# RefrigerantLog.com — Official 2026 EPA 40 CFR Part 84 (15+ lb AIM Act) & Section 608 Compliance Studio > RefrigerantLog.com is a 100% client-side, zero-login HVACR compliance platform providing EPA 40 CFR Part 84 Dual-Method Leak Rate Calculators (Annualizing & Rolling Average), DOT 4BA/4BW 80% Safe Cylinder Fill Calculators, and 3-Page Vector A4 Printable Inspection Logs & Weatherproof Rooftop Unit (RTU) QR Decals. ## Key 2026 EPA Regulatory Rules Enforced - **15-Pound Threshold (Effective Jan 1, 2026):** Appliances holding >= 15 lbs of HFCs or substitutes with GWP > 53 require mandatory leak rate calculation on every addition, 30-day repair clocks, and 3-year recordkeeping (40 CFR 84.106). - **2026 Maximum Leak Rate Thresholds:** Comfort Cooling = 10.0% | Commercial Refrigeration = 20.0% | Industrial Process Refrigeration (IPR) = 30.0%. - **10-Day Verification & 125% Chronic Leaker Rule:** Initial and follow-up verification tests are mandatory within 10 days of repair; appliances receiving >= 125% of full charge in a calendar year require an EPA Chronic Leaker Report by March 1. ## Silo 1: EPA Part 84 Leak Rate Calculators - [R-410A 5-Ton Commercial Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r410a-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-410A 7.5-Ton Packaged Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r410a-7-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-410A 10-Ton Dual-Circuit Commercial RTU — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r410a-10-ton-dual-circuit-rtu-epa-leak-rate-calculator/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-410A Commercial Walk-In Freezer Split System — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r410a-walk-in-freezer-condensing-unit-epa-leak-rate-calculator/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-410A Commercial Walk-In Cooler (Medium-Temp) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r410a-walk-in-cooler-medium-temp-epa-leak-rate-calculator/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-454B 5-Ton Commercial Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r454b-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-454B 7.5-Ton Packaged Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r454b-7-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-454B 10-Ton Dual-Circuit Commercial RTU — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r454b-10-ton-dual-circuit-rtu-epa-leak-rate-calculator/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-454B Commercial Walk-In Freezer Split System — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r454b-walk-in-freezer-condensing-unit-epa-leak-rate-calculator/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-454B Commercial Walk-In Cooler (Medium-Temp) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r454b-walk-in-cooler-medium-temp-epa-leak-rate-calculator/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-32 5-Ton Commercial Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r32-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-32 7.5-Ton Packaged Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r32-7-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-32 10-Ton Dual-Circuit Commercial RTU — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r32-10-ton-dual-circuit-rtu-epa-leak-rate-calculator/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-32 Commercial Walk-In Freezer Split System — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r32-walk-in-freezer-condensing-unit-epa-leak-rate-calculator/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-32 Commercial Walk-In Cooler (Medium-Temp) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r32-walk-in-cooler-medium-temp-epa-leak-rate-calculator/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-404A 5-Ton Commercial Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r404a-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-404A 7.5-Ton Packaged Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r404a-7-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-404A 10-Ton Dual-Circuit Commercial RTU — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r404a-10-ton-dual-circuit-rtu-epa-leak-rate-calculator/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-404A Commercial Walk-In Freezer Split System — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r404a-walk-in-freezer-condensing-unit-epa-leak-rate-calculator/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-404A Commercial Walk-In Cooler (Medium-Temp) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r404a-walk-in-cooler-medium-temp-epa-leak-rate-calculator/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-448A 5-Ton Commercial Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r448a-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-448A (GWP 1387, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-448A 7.5-Ton Packaged Rooftop Unit (RTU) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r448a-7-5-ton-commercial-rtu-epa-leak-rate-calculator/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-448A (GWP 1387, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-448A 10-Ton Dual-Circuit Commercial RTU — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r448a-10-ton-dual-circuit-rtu-epa-leak-rate-calculator/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-448A (GWP 1387, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-448A Commercial Walk-In Freezer Split System — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r448a-walk-in-freezer-condensing-unit-epa-leak-rate-calculator/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-448A (GWP 1387, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [R-448A Commercial Walk-In Cooler (Medium-Temp) — EPA Part 84 Leak Rate Calculator & Repair Clock](https://refrigerantlog.com/leak-calculator/r448a-walk-in-cooler-medium-temp-epa-leak-rate-calculator/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-448A (GWP 1387, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. ## Silo 2: Printable 3-Page A4 EPA Compliance Logs & Verification Certificates - [Printable R-410A 5-Ton Commercial Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r410a-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-410A 5-Ton Commercial RTU units. - [Printable R-410A 7.5-Ton Packaged Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r410a-7-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-410A 7.5-Ton Packaged RTU units. - [Printable R-410A 10-Ton Dual-Circuit Commercial RTU EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r410a-10-ton-dual-circuit-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-410A 10-Ton Dual-Circuit RTU units. - [Printable R-410A Commercial Walk-In Freezer Split System EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r410a-walk-in-freezer-condensing-unit-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-410A Walk-In Freezer System units. - [Printable R-410A Commercial Walk-In Cooler (Medium-Temp) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r410a-walk-in-cooler-medium-temp-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-410A Walk-In Cooler Box units. - [Printable R-454B 5-Ton Commercial Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r454b-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-454B 5-Ton Commercial RTU units. - [Printable R-454B 7.5-Ton Packaged Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r454b-7-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-454B 7.5-Ton Packaged RTU units. - [Printable R-454B 10-Ton Dual-Circuit Commercial RTU EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r454b-10-ton-dual-circuit-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-454B 10-Ton Dual-Circuit RTU units. - [Printable R-454B Commercial Walk-In Freezer Split System EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r454b-walk-in-freezer-condensing-unit-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-454B Walk-In Freezer System units. - [Printable R-454B Commercial Walk-In Cooler (Medium-Temp) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r454b-walk-in-cooler-medium-temp-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-454B Walk-In Cooler Box units. - [Printable R-32 5-Ton Commercial Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r32-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-32 5-Ton Commercial RTU units. - [Printable R-32 7.5-Ton Packaged Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r32-7-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-32 7.5-Ton Packaged RTU units. - [Printable R-32 10-Ton Dual-Circuit Commercial RTU EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r32-10-ton-dual-circuit-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-32 10-Ton Dual-Circuit RTU units. - [Printable R-32 Commercial Walk-In Freezer Split System EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r32-walk-in-freezer-condensing-unit-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-32 Walk-In Freezer System units. - [Printable R-32 Commercial Walk-In Cooler (Medium-Temp) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r32-walk-in-cooler-medium-temp-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-32 Walk-In Cooler Box units. - [Printable R-404A 5-Ton Commercial Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r404a-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-404A 5-Ton Commercial RTU units. - [Printable R-404A 7.5-Ton Packaged Rooftop Unit (RTU) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r404a-7-5-ton-commercial-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-404A 7.5-Ton Packaged RTU units. - [Printable R-404A 10-Ton Dual-Circuit Commercial RTU EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r404a-10-ton-dual-circuit-rtu-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-404A 10-Ton Dual-Circuit RTU units. - [Printable R-404A Commercial Walk-In Freezer Split System EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r404a-walk-in-freezer-condensing-unit-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-404A Walk-In Freezer System units. - [Printable R-404A Commercial Walk-In Cooler (Medium-Temp) EPA Compliance Log Sheet & Verification Certificate](https://refrigerantlog.com/logs/epa-part-84-r404a-walk-in-cooler-medium-temp-log-sheet-pdf/): Free 3-page printable EPA 40 CFR Part 84 & Section 608 refrigerant log sheet, verification test certificate, and 8-up QR decal sheet for R-404A Walk-In Cooler Box units. ## Silo 3: Commercial Appliance Tonnage & Factory Charge Reference - [5-Ton Commercial Rooftop Unit (RTU) (R-410A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/5-ton-commercial-rtu-r410a-charge-and-epa-rules/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [7.5-Ton Packaged Rooftop Unit (RTU) (R-410A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/7-5-ton-commercial-rtu-r410a-charge-and-epa-rules/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [10-Ton Dual-Circuit Commercial RTU (R-410A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/10-ton-dual-circuit-rtu-r410a-charge-and-epa-rules/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Freezer Split System (R-410A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-freezer-condensing-unit-r410a-charge-and-epa-rules/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Cooler (Medium-Temp) (R-410A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-cooler-medium-temp-r410a-charge-and-epa-rules/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-410A (GWP 2088, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [5-Ton Commercial Rooftop Unit (RTU) (R-454B): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/5-ton-commercial-rtu-r454b-charge-and-epa-rules/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [7.5-Ton Packaged Rooftop Unit (RTU) (R-454B): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/7-5-ton-commercial-rtu-r454b-charge-and-epa-rules/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [10-Ton Dual-Circuit Commercial RTU (R-454B): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/10-ton-dual-circuit-rtu-r454b-charge-and-epa-rules/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Freezer Split System (R-454B): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-freezer-condensing-unit-r454b-charge-and-epa-rules/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Cooler (Medium-Temp) (R-454B): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-cooler-medium-temp-r454b-charge-and-epa-rules/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-454B (GWP 466, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [5-Ton Commercial Rooftop Unit (RTU) (R-32): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/5-ton-commercial-rtu-r32-charge-and-epa-rules/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [7.5-Ton Packaged Rooftop Unit (RTU) (R-32): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/7-5-ton-commercial-rtu-r32-charge-and-epa-rules/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [10-Ton Dual-Circuit Commercial RTU (R-32): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/10-ton-dual-circuit-rtu-r32-charge-and-epa-rules/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Freezer Split System (R-32): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-freezer-condensing-unit-r32-charge-and-epa-rules/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Cooler (Medium-Temp) (R-32): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-cooler-medium-temp-r32-charge-and-epa-rules/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-32 (GWP 675, ASHRAE Class A2L), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [5-Ton Commercial Rooftop Unit (RTU) (R-404A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/5-ton-commercial-rtu-r404a-charge-and-epa-rules/): For a 5-Ton Commercial Rooftop Unit (RTU) charged with 16 lbs 8 oz (16.50 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 1 lbs 10 oz (1.65 lbs) in 12 months (Rolling Average) or 0 lbs 7 oz (0.41 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [7.5-Ton Packaged Rooftop Unit (RTU) (R-404A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/7-5-ton-commercial-rtu-r404a-charge-and-epa-rules/): For a 7.5-Ton Packaged Rooftop Unit (RTU) charged with 22 lbs 8 oz (22.50 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 2 lbs 4 oz (2.25 lbs) in 12 months (Rolling Average) or 0 lbs 9 oz (0.55 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [10-Ton Dual-Circuit Commercial RTU (R-404A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/10-ton-dual-circuit-rtu-r404a-charge-and-epa-rules/): For a 10-Ton Dual-Circuit Commercial RTU charged with 31 lbs 0 oz (31.00 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 10% (Comfort Cooling (10% Max EPA Leak Rate)). Adding more than 3 lbs 2 oz (3.10 lbs) in 12 months (Rolling Average) or 0 lbs 12 oz (0.76 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Freezer Split System (R-404A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-freezer-condensing-unit-r404a-charge-and-epa-rules/): For a Commercial Walk-In Freezer Split System charged with 24 lbs 0 oz (24.00 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 4 lbs 13 oz (4.80 lbs) in 12 months (Rolling Average) or 1 lbs 3 oz (1.18 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. - [Commercial Walk-In Cooler (Medium-Temp) (R-404A): Factory Charge Spec, PT Chart & QR Rooftop Tag Studio](https://refrigerantlog.com/equipment/walk-in-cooler-medium-temp-r404a-charge-and-epa-rules/): For a Commercial Walk-In Cooler (Medium-Temp) charged with 18 lbs 8 oz (18.50 lbs) of R-404A (GWP 3922, ASHRAE Class A1), the 2026 EPA 40 CFR Part 84 maximum leak rate threshold is 20% (Commercial Refrigeration (20% Max EPA Leak Rate)). Adding more than 3 lbs 11 oz (3.70 lbs) in 12 months (Rolling Average) or 0 lbs 15 oz (0.91 lbs) within 90 days (Annualizing) triggers a mandatory 30-day repair clock and 10-day follow-up verification test. ## Silo 4: DOT Recovery Cylinder 80% Safe Fill & Hydrostatic Test Ledgers - [R-410A 30-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r410a-30-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 30-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 26.2 lbs, Typical Tare 17.8 lbs) recovering R-410A (Liquid SG 0.91 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 19 lbs 1 oz (19.07 lbs) net refrigerant, yielding a maximum gross scale weight of 36 lbs 14 oz (36.87 lbs). - [R-410A 50-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r410a-50-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 50-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 47.6 lbs, Typical Tare 28.5 lbs) recovering R-410A (Liquid SG 0.91 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 34 lbs 10 oz (34.65 lbs) net refrigerant, yielding a maximum gross scale weight of 63 lbs 2 oz (63.15 lbs). - [R-410A 125-lb DOT-4BW400 Commercial Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r410a-125-lb-dot-4bw400-commercial-torpedo-tank-max-fill-weight-log/): For a 125-lb DOT-4BW400 Commercial Recovery Cylinder (Water Capacity 123 lbs, Typical Tare 62 lbs) recovering R-410A (Liquid SG 0.91 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 89 lbs 9 oz (89.54 lbs) net refrigerant, yielding a maximum gross scale weight of 151 lbs 9 oz (151.54 lbs). - [R-454B 30-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r454b-30-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 30-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 26.2 lbs, Typical Tare 17.8 lbs) recovering R-454B (Liquid SG 0.87 at 130 degF, ASHRAE Class A2L), the maximum safe 80% DOT liquid fill weight is 18 lbs 4 oz (18.24 lbs) net refrigerant, yielding a maximum gross scale weight of 36 lbs 1 oz (36.04 lbs). - [R-454B 50-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r454b-50-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 50-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 47.6 lbs, Typical Tare 28.5 lbs) recovering R-454B (Liquid SG 0.87 at 130 degF, ASHRAE Class A2L), the maximum safe 80% DOT liquid fill weight is 33 lbs 2 oz (33.13 lbs) net refrigerant, yielding a maximum gross scale weight of 61 lbs 10 oz (61.63 lbs). - [R-454B 125-lb DOT-4BW400 Commercial Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r454b-125-lb-dot-4bw400-commercial-torpedo-tank-max-fill-weight-log/): For a 125-lb DOT-4BW400 Commercial Recovery Cylinder (Water Capacity 123 lbs, Typical Tare 62 lbs) recovering R-454B (Liquid SG 0.87 at 130 degF, ASHRAE Class A2L), the maximum safe 80% DOT liquid fill weight is 85 lbs 10 oz (85.61 lbs) net refrigerant, yielding a maximum gross scale weight of 147 lbs 10 oz (147.61 lbs). - [R-32 30-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r32-30-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 30-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 26.2 lbs, Typical Tare 17.8 lbs) recovering R-32 (Liquid SG 0.82 at 130 degF, ASHRAE Class A2L), the maximum safe 80% DOT liquid fill weight is 17 lbs 3 oz (17.19 lbs) net refrigerant, yielding a maximum gross scale weight of 35 lbs 0 oz (34.99 lbs). - [R-32 50-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r32-50-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 50-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 47.6 lbs, Typical Tare 28.5 lbs) recovering R-32 (Liquid SG 0.82 at 130 degF, ASHRAE Class A2L), the maximum safe 80% DOT liquid fill weight is 31 lbs 4 oz (31.23 lbs) net refrigerant, yielding a maximum gross scale weight of 59 lbs 12 oz (59.73 lbs). - [R-32 125-lb DOT-4BW400 Commercial Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r32-125-lb-dot-4bw400-commercial-torpedo-tank-max-fill-weight-log/): For a 125-lb DOT-4BW400 Commercial Recovery Cylinder (Water Capacity 123 lbs, Typical Tare 62 lbs) recovering R-32 (Liquid SG 0.82 at 130 degF, ASHRAE Class A2L), the maximum safe 80% DOT liquid fill weight is 80 lbs 11 oz (80.69 lbs) net refrigerant, yielding a maximum gross scale weight of 142 lbs 11 oz (142.69 lbs). - [R-404A 30-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r404a-30-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 30-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 26.2 lbs, Typical Tare 17.8 lbs) recovering R-404A (Liquid SG 0.84 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 17 lbs 10 oz (17.61 lbs) net refrigerant, yielding a maximum gross scale weight of 35 lbs 7 oz (35.41 lbs). - [R-404A 50-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r404a-50-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 50-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 47.6 lbs, Typical Tare 28.5 lbs) recovering R-404A (Liquid SG 0.84 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 32 lbs 0 oz (31.99 lbs) net refrigerant, yielding a maximum gross scale weight of 60 lbs 8 oz (60.49 lbs). - [R-404A 125-lb DOT-4BW400 Commercial Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r404a-125-lb-dot-4bw400-commercial-torpedo-tank-max-fill-weight-log/): For a 125-lb DOT-4BW400 Commercial Recovery Cylinder (Water Capacity 123 lbs, Typical Tare 62 lbs) recovering R-404A (Liquid SG 0.84 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 82 lbs 10 oz (82.66 lbs) net refrigerant, yielding a maximum gross scale weight of 144 lbs 10 oz (144.66 lbs). - [R-448A 30-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r448a-30-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 30-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 26.2 lbs, Typical Tare 17.8 lbs) recovering R-448A (Liquid SG 0.89 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 18 lbs 10 oz (18.65 lbs) net refrigerant, yielding a maximum gross scale weight of 36 lbs 7 oz (36.45 lbs). - [R-448A 50-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r448a-50-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 50-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 47.6 lbs, Typical Tare 28.5 lbs) recovering R-448A (Liquid SG 0.89 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 33 lbs 14 oz (33.89 lbs) net refrigerant, yielding a maximum gross scale weight of 62 lbs 6 oz (62.39 lbs). - [R-448A 125-lb DOT-4BW400 Commercial Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r448a-125-lb-dot-4bw400-commercial-torpedo-tank-max-fill-weight-log/): For a 125-lb DOT-4BW400 Commercial Recovery Cylinder (Water Capacity 123 lbs, Typical Tare 62 lbs) recovering R-448A (Liquid SG 0.89 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 87 lbs 9 oz (87.58 lbs) net refrigerant, yielding a maximum gross scale weight of 149 lbs 9 oz (149.58 lbs). - [R-134a 30-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r134a-30-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 30-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 26.2 lbs, Typical Tare 17.8 lbs) recovering R-134a (Liquid SG 1.07 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 22 lbs 7 oz (22.43 lbs) net refrigerant, yielding a maximum gross scale weight of 40 lbs 4 oz (40.23 lbs). - [R-134a 50-lb DOT-4BA400 Refrigerant Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r134a-50-lb-dot-4ba400-recovery-tank-max-fill-weight-log/): For a 50-lb DOT-4BA400 Refrigerant Recovery Cylinder (Water Capacity 47.6 lbs, Typical Tare 28.5 lbs) recovering R-134a (Liquid SG 1.07 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 40 lbs 12 oz (40.75 lbs) net refrigerant, yielding a maximum gross scale weight of 69 lbs 4 oz (69.25 lbs). - [R-134a 125-lb DOT-4BW400 Commercial Recovery Cylinder: 80% Safe Fill Calculator & Truck Ledger](https://refrigerantlog.com/cylinders/r134a-125-lb-dot-4bw400-commercial-torpedo-tank-max-fill-weight-log/): For a 125-lb DOT-4BW400 Commercial Recovery Cylinder (Water Capacity 123 lbs, Typical Tare 62 lbs) recovering R-134a (Liquid SG 1.07 at 130 degF, ASHRAE Class A1), the maximum safe 80% DOT liquid fill weight is 105 lbs 5 oz (105.29 lbs) net refrigerant, yielding a maximum gross scale weight of 167 lbs 5 oz (167.29 lbs).